12V power point timeout — F-150 FORScan mod (2015–2020)
Keeps the 12V power points live after the truck is shut off (or sets a 1-second timeout).
- Module
- BCM — Body Control Module (726)
- Model years
- 2015 2016 2017 2018 2019 2020
- Category
- Comfort
- Risk
- Low risk
- FORScan setting
- No named setting documented. Use As-Built Format.
- As-Built
BCM 726-39-01: 1194 x0xx xxxx (timeout disabled) / 0001 x1xx xxxx (enabled, 1 s)As published by the source below. Compare against your own backup; surrounding digits control other features.
Notes
A powered accessory left plugged in can drain the battery.
How to apply it
- Back up every module's As-Built data and keep the files somewhere safe.
- Connect FORScan with a battery maintainer on, ignition ON and engine OFF.
- Open Configuration and Programming, choose the BCM module, open As-Built Format and edit only the digit described by the source.
- Write, follow any module reset prompt, cycle the ignition, then confirm the feature and check for new trouble codes.