Power point timeout disable / duration — F-150 FORScan mod (2021–2026)
Keeps 12V power points live after shutdown (no timeout) or sets a custom timeout duration.
- Module
- BCM — Body Control Module (726)
- Model years
- 2021 2022 2023 2024 2025 2026
- Powertrain
- Gas (EcoBoost, 5.0L, V6), PowerBoost hybrid, Lightning EV
- Trim & equipment
- The 400 W outlet will not stay live with the engine off
- Lightning: not verified; values come from gas/PowerBoost trucks
- Category
- Comfort
- Risk
- Medium risk
- FORScan setting
- No named setting documented. Use As-Built Format.
- As-Built
Config: BCM 726-57-01 xxxx 00xx xx-- (disabled, always on) / xxxx 01xx xx-- (enabled, default). Duration: BCM 726-57-01 ABCD xxxx xx-- (seconds in hex, 0001=1 s)As published by the source below. Compare against your own backup; surrounding digits control other features.
Notes
Risk of battery drain. A 2022 owner found only the console charging port stayed live with timeout disabled; the 400W outlet will not work engine-off due to draw.
How to apply it
- Back up every module's As-Built data and keep the files somewhere safe.
- Connect FORScan with a battery maintainer on, ignition ON and engine OFF.
- Open Configuration and Programming, choose the BCM module, open As-Built Format and edit only the digit described by the source.
- Write, follow any module reset prompt, cycle the ignition, then confirm the feature and check for new trouble codes.